The WR series industrial thermocouple is a permanent installation sensor for measuring furnace, pipe, ladle and heat-treatment equipment temperatures up to 1800 °C. The model code defines the wire type, number of pairs, mounting fitting, junction box, protective tube diameter, accuracy class and insertion length.
| Item | Specification |
|---|---|
| Model code | WR □□□□□□□ – wire type, pairs, fitting, junction box, tube OD, accuracy class, L/l, material |
| Tube materials | A 20# carbon steel (-100~500 °C); B 1Cr18Ni9Ti (-200~900 °C); C Cr25Ti (-400~1000 °C); D high-alumina (0~1300 °C); R corundum CT1 (0~1600 °C); F MoSi2 MS (0~1600 °C); G tantalum tube (0~2300 °C); H heat-resistant alloy; I corrosion-resistant alloy |
| Standard length range | L 225 – 2650 mm (OD code 0 = Φ16, 1 = Φ20, 2 = Φ25, 3 = tapered) |
| Response time | Metal tube < 60 s; non-metal tube < 120 s; double-layer non-metal < 210 s |
| External exposure L0 | 100 / 150 / 200 / 250 mm (150 standard); socket box 30 / 50 / 100 mm; tapered welded L0 = 230 mm |
| Working pressure of fittings | Carbon steel: atmospheric for codes 1/3/5, ≤1.0 MPa for 2/4 |
| Standard | JB/T9238-1999, class I / II / III tolerances |
Heat treatment furnaces, annealing and tempering lines, non-ferrous melting, kilns, ladles, tundishes, salt-bath and quench equipment.
Provide the complete model code, or state: wire type, fixing device, junction box type, tube material and OD, accuracy class and L/l. Special lengths and non-standard materials are quoted on request.
Heat treatment furnaces, annealing and tempering lines, non-ferrous melting, kilns, ladles, tundishes, salt-bath and quench equipment.