Thermal analysis sample cup (also known as quik cup, CE cup or carbon cup) model 4012 is the expendable measuring cup used with a furnace-front thermal analyser. Molten iron is poured into the cup; the integrated thermocouple records the cooling curve and the analyser calculates the composition from the thermal arrest. Model 4012: Determination of CEL, C and Si after nodularization.
| Item | Specification |
|---|---|
| Measuring range | 1250 °C – 1370 °C |
| Carbon equivalent (CEL) | (2.2 – 5.0) ± 0.05% |
| Carbon content (C) | (2.1 – 4.8) ± 0.05% |
| Silicon content (Si) | (0.2 – 4.5) ± 0.1% |
| Test time | 60 s |
| Cup body | Moulded refractory cup with tellurium coating option |
| Thermocouple | Precision K-type thermocouple integrated in the cup base |
Furnace-front control of molten iron composition in foundries: ductile iron and grey iron melting, spheroidizing treatment verification, charge correction and quality records.
Order by model number (4012). Please indicate required quantity, tellurium coating and the thermal analyser model in use so that the connector can be matched.
Furnace-front control of molten iron composition in foundries: ductile iron and grey iron melting, spheroidizing treatment verification, charge correction and quality records.
AMSUO 11-Piece Quick-Change Mini Cutting Disc Set — 1-1/2" (38.1 mm)
AMSUO Carbide Rotary Burr Sets — Full Shape Range (A/B/C/D/E/F/G/H/L/M), Single & Double Cut, Standard & Metric
AMSUO 5-Piece Screw Extractor Set (EXT-5) — Milled 40Cr Alloy Steel, Reverse Spiral Flutes, Hex Shank, for Broken Bolt & Stud Removal
AMSUO Rotary Burrs — Coarse Cut Metric Series, 6 Shapes, 6–11.85 mm Heads
Copyright © 2026 Amsuo Technology Limited. All rights reserved — Privacy Policy